Educational School Website / About Us / Our Team / Blog / Careers / Contact Us
Dublin Office: +353 1 460 7600
Cork Office: +353 21 233 9410
0
Cart
/
Empty
Your cart
There are no more items in your cart
Spectrophotometer NANOCOLOR Advance
Manufacturer Ref: Macherey Nagel
EMN919750
POA
- Price reduced from €2580 to €1999
- Our Special Prices are available untill 31.06.2021
- Spectrophotometer NANOCOLOR® Advance includes:-
- manual (quick start guide),
- protective cover,
- power supply unit with country specific adapters,
- USB stick,
- calibration cuvette,
- certificate and cleaning cloth in cardboard box.
- Smart into the future: The spectrophotometer NANOCOLOR® Advance combines the most important features of our portable compact photometer PF-12Plus and our high-precision spectrophotometer NANOCOLOR® VIS II.
- It provides precise and reliable measurement results in the daily laboratory routine and can also be used mobile due to its rechargeable battery.
- With its wavelength spectrum of 340–800 nm it allows the measurement of all photometrically evaluable test kits from MACHEREY‑NAGEL.
- The NANOCOLOR® Advance can therefore be used universally in the entire spectrum of water and wastewater analysis.
Dimensions
325 x 280 x 130 mm (L x W x H)
Type
Spectrophotometer with Reference Detector Technology (RDT)
Display
Backlit display
Wavelength Accuracy
± 2 nm
Spectral Bandwidth
< 4 nm
Light Source
Halogen lamp
Wavelength Range
340 nm–800 nm
Wavelength resolution
1 nm
Wavelength reproducibility
+/- 0.1 nm
Photometric range
+/- 3.0 A in the range 340–800 nm
Languages
DE / EN / FR / ES / PT / PL / NL
Photometric Accuracy
0.003 A at 0.0–0.5 A; 1 % at 0.5–2.0 A
Operation
Barcode technology; icon-based display menu navigation; capacitive touch screen
Interfaces
LAN (CAT 6; only use shielded cables with a maximum length of 20 m) 2 x USB (Host)
Protection Class
IP 67
Optical system
Single beam photometer with grating monochromator
Turbidity measurement
Nephelometric turbidity measurement (16 mm and 24 mm) 1–1000 NTU
Cuvette slot
Tube test 16 mm and 24 mm OD;Standard test 10 mm
External light
Insensitive; open cuvette slot
Data memory
1000 Measured values/spectra; GLP-conform
Update
Via USB stick
Wavelength calibration
Automatically
Wavelength selection
Automatically/Barcode/manually
Scan speed
1 complete Scan < 3 min
Photometric linearity
< 0.5 % at 0.5–2.0 A; ≤ 1 % at > 2 A with neutral glass filters at 546 nm
Scattered light
< 0.5 %
Measurement modes
Over 200 pre-programmed tests and special methods; 99 fully
programmable methods; absorbance; transmission; factor; kinetics;2-point calibration; scan; nephelometric turbidity measurement
EMN919750
If you require a Safety Data Sheet for any products purchased from Lennox please contact us at customerservice@lennox.ie. If possible, please include the name and code of the items.